1. Home
  2. Load moment indicator (LMI)

Operational aids

Load moment indicator: what an LMI does and when it is required

The LMI is the crane's own running check on the load chart. It is also an operational aid under OSHA's rule, which means there is a deadline for fixing it and a fallback when it is down.

The short answer

A load moment indicator senses the overturning moment, which is the load times the radius, compares it with the crane's rated capacity, and shows how close you are. A load moment limiter goes a step further and cuts out the functions that would increase the load. OSHA requires cranes built after March 29, 2003 and rated over 6,000 pounds to have a load weighing device, an LMI or a limiter. A failed one must be repaired within 30 calendar days.

Checked November 2026 against the text of 29 CFR 1926.1416, 29 CFR 1926.1415 and 29 CFR 1926.1401.

Indicator or limiter?

OSHA defines both in 1926.1401. It also calls them rated capacity indicators and rated capacity limiters.

Load moment devices as OSHA defines them
DeviceWhat it does
Load moment (rated capacity) indicatorSenses the overturning moment on the crane, which is load multiplied by radius. Compares it with the rated capacity and tells the operator what share of capacity is in use
Load moment (rated capacity) limiterSenses the same thing. When rated capacity is reached, it shuts off power to the functions that would increase the loading: hoisting up, telescoping out or luffing out
Load weighing deviceMeasures the weight on the hook

Source: 29 CFR 1926.1401.

The moment is why an LMI needs to know the configuration. The same load is a bigger moment at a longer radius, so the device has to be set for the boom length, outrigger position and parts of line in use.

When OSHA requires one

Load weighing and similar devices, 1926.1416(e)(4)
Which cranesEquipment built after March 29, 2003 with a rated capacity over 6,000 pounds. Derricks and articulating cranes have their own rules
What it must haveAt least one of: a load weighing device, a load moment or rated capacity indicator, or a load moment or rated capacity limiter
CategoryCategory II operational aid
Repair deadline30 calendar days after the deficiency occurs. If a part is ordered within 7 days, 7 days after it arrives
MeanwhileThe weight of the load is found from a reliable source, by a calculation method or by other means, and given to the operator before the lift
Tower cranesA load moment limiting device is a Category I aid, with the 7-day deadline

Sources: 29 CFR 1926.1416 and 29 CFR 1926.1435.

Free OECP practice test

25 questions, no sign-up, every answer explained.

Start now

7 practice questions on LMIs and operational aids

Pick an answer to see whether you are right and why. These are original practice questions from the Crane Exam Prep question bank, not actual exam questions.

  1. Mobile Crane Essentials

    1. If the boom length indicator stops working, how can boom length be verified?

    Show answer

    Answer: D. With a tape measure. If the boom length indicator fails, you can use a tape measure to verify boom length.

  2. Rigging

    2. What must be checked before trusting a dynamometer or crane load-indicating system for weighing a load?

    Show answer

    Answer: A. Its calibration. The handbook repeatedly notes dynamometers, cable weighing scales, and crane load indicating or moment systems must be checked for calibration.

  3. OSHA 1926 Subpart CC

    3. According to OSHA 1926.1416, the temporary alternative measure for a non-working boom angle or radius indicator is:

    Show answer

    Answer: A. Radii or boom angle must be determined with a measuring device. 1926.1416(e)(1) allows operations to continue if radii or boom angle are determined by measuring with a measuring device.

  4. Operation Aids

    4. If an operational aid such as the anti-two-block device fails during a lift, the operator should:

    Show answer

    Answer: D. stop until the aid is repaired or approved temporary measures are set. Under 1926.1416(c) the operator must safely stop until the temporary alternative measures specified in 1926.1416 (for an ATB: mark the cable and use a spotter when extending the boom) are in place or the device works again.

  5. OSHA 1926 Subpart CC

    5. According to OSHA 1926.1416, the requirements for a boom hoist limiting device apply to equipment manufactured after what date?

    Show answer

    Answer: D. December 16, 1969. 1926.1416(d)(1)(i) requires a boom hoist limiting device for equipment manufactured after December 16, 1969; older equipment must use at least one of the temporary alternative measures.

  6. Operation Aids

    6. A hoist drum rotation indicator is required when…

    Show answer

    Answer: C. The hoist drum is not visible from the operator's station. If the operator cannot see the hoist drum from the station, a drum rotation indicator is required; the alternative is marking the drum with mirrors or cameras as needed.

  7. OSHA 1926 Subpart CC

    7. According to OSHA 1926.1401, the difference between a load moment indicator and a load moment limiter is that the limiter:

    Show answer

    Answer: D. Shuts off power to functions that can increase the severity of loading when rated capacity is reached, while the indicator only warns. Per 1926.1401, a load moment indicator senses overturning moment and warns of approaching overload; a load moment limiter shuts off power to load-increasing functions (hoisting, telescoping out, luffing out) when rated capacity is reached, while lowering functions remain operational.

Operational aids and their repair deadlines

Operational aids give the operator information or take control of a function. Each has a temporary alternative measure for use while it is being repaired.

Operational aids in 29 CFR 1926.1416
Operational aidCategoryRepair within
Boom hoist limiting deviceI7 days
Luffing jib limiting deviceI7 days
Anti-two-block deviceI7 days
Boom angle or radius indicatorII30 days
Jib angle indicator, with a luffing jibII30 days
Boom length indicator, on telescopic boomsII30 days
Load weighing device, LMI or limiterII30 days
Outrigger or stabilizer position sensor, on equipment built after November 8, 2011II30 days
Hoist drum rotation indicator, where the drum is not visible, on equipment built after November 8, 2011II30 days

Source: 29 CFR 1926.1416. Days are calendar days.

Safety devices are different

OSHA lists safety devices separately, in 1926.1415. The crane cannot operate unless every one of them works, and there is no alternative measure:

  • A crane level indicator
  • Boom stops, except on hydraulic booms
  • Jib stops
  • Locks on foot pedal brakes
  • An integral holding device or check valve on hydraulic outrigger and stabilizer jacks
  • Rail clamps and rail stops on rail-mounted equipment
  • A horn

An exam question that asks what to do when a device fails turns on which list it is on. Boom stop broken: stop. LMI broken: verify the load weight another way and repair within 30 days.

What an LMI does not do

An LMI is an aid. OSHA still requires the operator to stay within rated capacity and to know the load weight. Under 1926.1417, if a check with a load weighing device or LMI shows the load is over 75% of rated capacity at the longest radius to be used, the operator does not proceed until the weight is verified.

It also depends on being set up correctly, and it does not read the ground under the outriggers. How to read a load chart is still the skill underneath it.

FAQ

Load moment indicator questions

What does LMI stand for on a crane?
Load moment indicator. OSHA also calls it a rated capacity indicator.
What does a load moment indicator do?
It senses the overturning moment on the crane, which is the load multiplied by the radius, compares it with the rated capacity for the configuration, and shows the operator what share of capacity is being used.
Is an LMI required by OSHA?
Cranes built after March 29, 2003 with a rated capacity over 6,000 pounds must have at least one of a load weighing device, a load moment indicator or a load moment limiter.
Can I operate a crane if the LMI is not working?
Yes, for up to 30 calendar days, if the load weight is determined from a reliable source or by calculation and given to the operator before each lift.
What is the difference between an LMI and an RCL?
An indicator shows the operator how close the crane is to rated capacity. A rated capacity limiter also shuts off the functions that would increase the loading once capacity is reached.
Are these real exam questions?
No. They are original practice questions written from the OSHA rules and ASME B30 standards that crane exams draw on. OECP does not release its questions, and this site is not affiliated with OECP or the IUOE.

Keep going

One free practice test shows you where you stand.

25 questions. No sign-up. Every answer explained.

Start the free practice test
More practice questionsFree account, no card
Open the app