Wire rope inspection and removal criteria

Crane rope wears out from the outside in and from the inside out, and OSHA's rule gives exact counts for when it has to come off. The numbers differ for running rope, rotation resistant rope and standing rope, which is why they make good exam questions.

The short answer

Under 29 CFR 1926.1413, running rope comes out of service at six randomly distributed broken wires in one rope lay, or three broken wires in one strand in one lay. Rotation resistant rope: two in six rope diameters or four in 30. Any rope: a diameter reduction of more than 5%. A competent person inspects the rope each shift.

Checked November 2026 against the text of 29 CFR 1926.1413 and 29 CFR 1926.1414.

OSHA's three categories of deficiency

Wire rope deficiencies in 29 CFR 1926.1413(a)
CategoryWhat is foundWhat happens
ISignificant distortion such as kinking, crushing, unstranding, birdcaging or core failure. Significant corrosion. Electric arc or heat damage. Improperly applied end connections. Corroded, cracked, bent or worn end connectionsA competent person decides at once whether it is a safety hazard. If it is, the rope is out of service until it is replaced, or the damaged part is cut off
IIVisible broken wires at the counts below, or a diameter reduction of more than 5% from nominalOut of service until the manufacturer's criterion is met, the rope is replaced or the damaged part is cut off
IIICore protrusion or distortion in rotation resistant rope that points to core failure. Prior electrical contact with a power line. A broken strandOut of service until replaced. A localized defect can be cut off, but not where the rope touched a power line

Source: 29 CFR 1926.1413, paragraph (a).

Cutting off a damaged section is allowed. Splicing the rope is not. After cutting, at least two full wraps must still be on the drum with the load or boom in its lowest position.

Broken-wire counts by rope type

Category II broken-wire criteria
RopeRemove from service at
Running wire ropeSix randomly distributed broken wires in one rope lay, or three broken wires in one strand in one rope lay
Rotation resistant ropeTwo randomly distributed broken wires in six rope diameters, or four in 30 rope diameters
Pendants and standing wire ropeMore than two broken wires in one rope lay beyond the end connections, or more than one broken wire in a rope lay at an end connection

Source: 29 CFR 1926.1413, paragraph (a)(2)(ii).

A rope lay is the length along the rope in which one strand makes a complete turn around the core. Rope diameters are just that: on a 3/4 inch rope, six diameters is 4.5 inches.

Free OECP practice test

25 questions, no sign-up, every answer explained.

Start now

8 practice questions on wire rope

Pick an answer to see whether you are right and why. These are original practice questions from the Crane Exam Prep question bank, not actual exam questions.

  1. Wire Rope

    1. Besides 2 broken wires in 6 rope diameters, rotation-resistant rope is also removed at how many broken wires in 30 diameters?

    Show answer

    Answer: D. 4. Rotation-resistant running rope is retired at 2 broken wires in 6 rope diameters OR 4 broken wires in 30 rope diameters.

  2. Crane Inspector — Core

    2. On running rope (rope that bends over sheaves), the number of randomly distributed broken wires in one rope lay that requires removal from service is:

    Show answer

    Answer: C. 6. Six randomly distributed broken wires in one lay is a standard running-rope removal criterion.

  3. Wire Rope

    3. According to ASME B30.2, the removal criteria for regular lay wire rope is four broken wires in one strand, in one lay or twelve randomly distributed broken:

    Show answer

    Answer: C. Wires in one lay. B30.2 retirement criteria call for removal at twelve randomly distributed broken wires in one rope lay, or four broken wires in one strand in one lay.

  4. Wire Rope

    4. A wire rope that was kinked but has been “straightened out” is…

    Show answer

    Answer: B. Still ruined — it must be removed from service. A kink permanently displaces the strands and destroys the rope’s cross-section. Straightening hides it; it doesn’t fix it.

  5. Wire Rope

    5. When should the first (baseline) diameter measurements of a new wire rope be taken?

    Show answer

    Answer: B. After the time of the rope's initial loading. New rope "pulls down" from its original diameter when first loaded, so baseline measurements should be made and recorded after initial loading.

  6. Wire Rope

    6. What is one rope lay?

    Show answer

    Answer: B. The length along the rope in which a single strand makes one complete spiral, or turn, around the core. A rope lay is the length along the rope that one strand requires to make one complete spiral around the core.

  7. Wire Rope

    7. Per OSHA, how often must a thorough inspection of wire rope be made, with dated records kept?

    Show answer

    Answer: A. At least once a month. A thorough inspection must be made at least once a month with a full written, dated, and signed report kept on file.

  8. Wire Rope

    8. A wire rope SLING must be removed from service when there are how many broken wires in ONE STRAND in one rope lay?

    Show answer

    Answer: C. 5. Per OSHA 1910.184 / ASME B30.9, a wire rope sling is retired at 5 broken wires in one strand in one lay (or 10 randomly distributed in one lay).

When wire rope is inspected

Inspection schedule in 29 CFR 1926.1413
InspectionWhoWhat
Each shiftCompetent personA visual inspection of rope likely to be in use during the shift. Untwisting the rope or booming down is not required
MonthlyCompetent personThe shift inspection again, documented
Annual, at least every 12 monthsQualified personThe full length of the rope, including sections that are normally hidden, reverse bends and sections that pass over sheaves

Source: 29 CFR 1926.1413.

The rule tells the inspector where to look hardest: rotation resistant rope, boom hoist rope at reverse bends, the flange and crossover points on drums, terminal ends, and rope at saddles and equalizer sheaves.

Rope rules that go with inspection

From 29 CFR 1926.1414 and 1926.1417
Wraps on the drumNever fewer than two full wraps when the load or boom is lowered
Rotation resistant rope typesType I has at least 15 outer strands, Type II at least 10, Type III no more than nine
Rotation resistant design factorAt least 3.5. Type I at least 5 unless the manufacturer approves otherwise
Boom hoist reevingNo fiber core rope, except on derricks
LubricantsLubricants that hinder inspection are not to be used
Tag outWhen a rope is removed from service, the equipment or the hoist is tagged out until it is repaired or replaced

Sources: 29 CFR 1926.1413, 29 CFR 1926.1414 and 29 CFR 1926.1417.

Other standards use other numbers

Do not carry these counts across to a different rule. Wire rope slings in construction follow OSHA 1926.251, which takes a sling out of service when visible broken wires exceed 10% of the total in any length of eight diameters. Sling inspection.

Overhead cranes follow 1910.179 and ASME B30.2. One of the practice questions above gives B30.2's count for running rope, and it is not six and three. Overhead crane inspection.

FAQ

Wire rope inspection questions

How many broken wires before a crane rope must be replaced?
For running rope under OSHA 1926.1413: six randomly distributed broken wires in one rope lay, or three broken wires in one strand in one rope lay.
What is the removal criteria for rotation resistant rope?
Two randomly distributed broken wires in six rope diameters, or four randomly distributed broken wires in 30 rope diameters.
How much diameter loss is allowed in wire rope?
A reduction of more than 5% from nominal diameter is a Category II deficiency and takes the rope out of service.
How often is crane wire rope inspected?
Each shift and each month by a competent person, and at least every 12 months over its full length by a qualified person.
Can damaged wire rope be repaired?
It cannot be spliced. Where the damage is localized, the damaged part can be cut off and the rest used, as long as two full wraps stay on the drum. Rope that has contacted a power line cannot be repaired.
What is birdcaging?
A distortion in which the outer strands of a wire rope open up and bulge away from the core. OSHA lists it as a Category I deficiency.
Are these real exam questions?
No. They are original practice questions written from the OSHA rules and ASME B30 standards that crane exams draw on. OECP does not release its questions, and this site is not affiliated with OECP or the IUOE.